Intraoperative Neurophysiological Monitoring System Nim Eclipse Medtronic

Brand:

Intraoperative Neurophysiological Monitoring System Nim Eclipse Medtronic

The device is specially designed for detection, stimulation, recording and generally for Intraoperative Neurophysiological Monitoring of the Nerves of the Brain and Spine by applying the following Evoked Potentials in Brain and Spine surgeries.

 

Applications & Functions

• Intraoperative neurophysiological monitoring of the brain and spine
• Motor Evoked Potentials (MEP)
• Somatosensory Evoked Potentials (SSEP)
• Electromyography (EMG)
• Electroencephalography (EEG)
• Visual Evoked Potentials (VEP)
• Auditory Evoked Potentials (BAEP)
• Screw inspection Spine (Screw Test)
• Nerve Root Test
• Brain Mapping

 

System & Structure

• Main control unit (controller)
• Computer unit (laptop)
• 2 recording units
• Stimulation unit

 

Channels & Stimulation

• 32 channels of simultaneous stimulation and recording
• MEP, SSEP, VEP, BAEP support
• 8-channel high-intensity stimulation unit
• 1 low-intensity channel
• Bipolar or unipolar neurostimulator (probe)
• Transcranial motor nerve stimulation

 

Monitoring & Security

• Continuous EMG and EEG recording in 32 channels
• Simultaneous data processing and storage
• Audible nerve stimulation warning
• Graphic display on the screen
• Visual electrode disconnection warning
• Automatic channel identification via electrodes
• Warning for incorrect electrode values
• Self-check system at startup

 

Software & Processing

• Processing software (filters, amplification, noise reduction)
• Detection of artifacts and false signals
• Display of alerts on the screen
• Data logging for further analysis
• Saving settings per procedure
• Electrode placement instructions with images

 

Specialized Functions

• Automated Screw Test
• Cerebral cortex mapping
• Anesthesia status control (TOF)
• Simultaneous operation with bipolar diathermy without EMG loss
• Parasite cut-off system from other operating room devices

 

Types of Stimulations

• Electrical stimulation
• Mechanical stimulation
• Thermal stimulation
• Separate visual and audio display for each type

 

Settings & Control

• Stimulation current intensity adjustment
• Measurement of channeled current
• Electrode status check
• Horizontal time analysis
• Vertical potential analysis
• Sound signal intensity adjustment
• Response delay settings
• Stimulation frequency settings
• Stimulation rate settings (fast / slow)

 

Connectivity and Extensions

• Network operation (LAN, Ethernet)
• Connection to a second monitor
• Audio outputs for headphones
• Auxiliary power output for printer up to 250VA

 

Technical Specifications

• Operating voltage 220V / 50Hz
• User manual in Greek