R37a clinical audiograph RESONANCE Italy

Brand:

R37a clinical audiograph RESONANCE Italy

The clinical audiologist performs: Pure tone test, Autothreshold, ABLB, Speech, Stenger, DLI,SISI, Bekesy, Tone Decay, MLB, Multifrequency, GAP, DLF, high frequency at 20 KHz

 

·         It has a built-in thermal printer

·         A pdf report is created directly from the device and saved to USB, with the ability to add patient details and comments via a wireless keyboard (optional)

·         Connection Ports Nr. 1 USB host type A. Nr.1 ​​USB slave type B

·         Windows compatible software Resonance MDS Management Data Suite

·         Power supply 110-240 V AC 50/60 Hz 40VA

·         Dimensions 370x290x180mm and weight: 3.5 kg.

·         ISO 13485, ISO 9001, MDD 93/42/EEC, Class IIa, IEC 60601-1, EMC: IEC 60601-1-2,

 

Audiometry features

·         Frequency range:

125-8000Hz (με DD45)

125-12500Hz (με HDA280)

8000-20000Hz (με HDA300)

250-8000Hz (με B71W)

·         Range from -10 to 120dB HL

·         Frequency Accuracy <0.5%

·         Distortion Accuracy <1%

·         Linear attenuation with 1dB step for every 5dB with a maximum of 3dB for the entire range

·         Ακοομετρία Καθαρού τόνου: ημιτονικό σήμα από 125 εώς 8KHz (ως 20KHz για HDA300)

·         Audiometry with frequency modulation: +- 5% of the frequency of the modulated signal, 5 Hz signal modulation

Narrowband noise: 24dB/ filtered noise

·         Speech noise: 1 KHz 12dB/filtered noise

 

Outputs

·         ACR,ACL: 10Ω DD45 headphones, alternatively HDA280 Sennheiser. IP30 headphones

·         ACR,ACL up to 20KHz: HDA300 Sennheir

·         BC: B71W Radioear, B81

·         600Ω free field output

 

Viewing and shaping stimuli

·         Display: Normal, inverted, extended (sounds are presented for 1 second from 20 dB below maximum)

·         Modulation: Continuous or pulsed signal (0.5, 1, 2 Hz) DLI levels

0.1 in steps from 20dB to 1.0 dB, 1.5, 2,3,4,5 dB

·         DLI increment levels: 0.5, 1, 2 Hz

·         SISI gain levels: 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5 dB

·         Bekesy: Continuous, pulsed  Examination duration 30 and 60 seconds

 

Basic accessories

·         DD45, ADC or HDA280 headphones and audiometry test

·         HDA300 headphones for high frequency testing

·         B71W bone conductor

·         Converter

·         Operator headset with microphone

·         Patient microphone for response

·         Internal speaker for monitoring

·         Patient response button

·         Built-in thermal printer

·         1 roll of paper with a width of 112 mm.

·         Power cable (110-220 V)

·         Protective cover

·         User Manual

·         SD card with speech material in multiple languages

·         Resonance MDS software including NoAH (demo version)

·         1 extra fuse