Brand:

BM780 radio frequency device

The BM 780 II radiofrequency device can be used as monopolar or bipolar diathermy, operating in the radio wave range for more precise cutting, strong hemostasis and reduced tissue destruction.

The radiofrequency device is suitable for the treatment of nasal turbinate hypertrophy, for the shrinkage of the soft palate, uvula, posterior arch, base of the tongue, etc. as well as for dermatological diseases. It has suitable bipolar probes - electrodes for submucosal placement and a wide range of monopolar electrodes (bronchi, pins, balls, etc.).

In more detail:

Radiofrequency treatment has the following advantages:

  • Easy to handle by the user.
  • Maximum safety for the patient.
  • Bloodless, painless and rapid procedure (e.g. palate 9 seconds after anesthesia, concha 5-9 seconds).
  • Shrinkage of the mucosa without tissue necrosis (protection system with audible alarm).
  • Quick recovery with noticeable results.

The Sutter system features and operates with multi-use, re-sterilizable bipolar and monopolar radiofrequency electrodes, in order to achieve the optimal result depending on the procedure.

In addition to being a radiofrequency generating device, it can function as a monopolar as well as a bipolar diathermy, thus providing the user with a complete solution for private practice, outpatient practice and operating room.

As an additional safety feature for the user and the patient, the system features the “Auto RF” feature which, when using radio frequencies in the field, automatically intervenes and adjusts the intensity of the transmitted energy by calculating the structure and condition of the tissue, through its resistance.

The RF Select Sutter central unit has the following functions with the corresponding indications:

  • Rheostat – selector of the intensity of the transmitted energy, graduated from 1 to 10.
  • Cutting, cutting with hemostasis, cauterization and hemostasis in monopolar and precise cutting and hemostasis in bipolar.
  • Indication for connecting the grounding plate.
  • Indication of the selected type of unipolar and bipolar operation.
  • Connection points for the single-pole and double-pole cable with handle, as well as the connection point for the grounding plate.

The handles and electrodes available are multi-purpose, lightweight and have an ergonomic design for easy and precise use by the Doctor.

They are sterilized by the following methods.

  • Steam Oven
  • Creature
  • Gas

The device is accompanied by a 2-year warranty, CE MARK and is provided by our Company, preventive maintenance at regular intervals and immediate service (24 hours) in the event of a malfunction.

THE DEVICE CONSISTS OF THE FOLLOWING:

  • CENTRAL UNIT (RF GENERATOR). CODE:360080-01
  • FOOTSWITCH. ΚΩΔΙΚΟΣ : 360105
  • MONOPOLAR STYLET DIAMETER 1.6mm. ΚΩΔΙΚΟΣ 360215
  • MULTIPURPOSE MONOPOLAR ELECTRODES 1.6mm

    CODE: 360510 (STRAIGHT)

     CODE:  360511 (CONVEX)

  • MONOPOLAR STYLET DIAMETER 2.4mm. CODE 360218
  • MULTIPURPOSE MONOPOLAR ELECTRODES 2.4mm

      CODE: 360340(STRAIGHT)

    CODE: 360342 (CURVED)

  • GROUNDING PLATE CODE: 360226
  • BIPOLAR CONNECTION CABLE. CODE: 370138L
  • MULTIPURPOSE BIPOLAR RADIOFREQUENCY ELECTRODE WITH 10MM LENGTH PINS FOR HYPERTROPHY OF THE NASAL CONCHA. CODE:700462
  • MULTI-PURPOSE RADIOFREQUENCY BIPOLAR ELECTRODE FOR MALTA HYPERION. CODE: 700495
  • MULTI-PURPOSE BIPOLAR RADIOFREQUENCY ELECTRODE FOR THE POSTERIOR CHAMBER. CODE: 700496
  • MULTI-PURPOSE RADIOFREQUENCY BIPOLAR ELECTRODE FOR LINGUAL TONSIL DESCRIPTION. CODE: 700497
  • MULTI-PURPOSE RADIOFREQUENCY BIPOLAR ELECTRODE FOR THE BASE OF THE TONGUE. CODE: 700499
  • BIPOLAR FORCEPS WITH A TOTAL LENGTH OF 16.5cm, WORKING LENGTH OF 6.5cm AND TIP DIAMETER OF 0.7mm.

CODE: 700168

  • ELECTRONIC STOPWATCH. CODE: 990027
  • MOUNTING TRAY CODE: 800000
  • STERILIZATION CASE CODE: 701756
  • GROUNDING PLATE RETAINING BANDAGE CODE: 360345
  • BIPOLAR SUCTION FORCEPS FOR CAPTURE AND PREPARATION FOR TONSILECTOMY CODE:700960

 Technical characteristics:

OPERATING VOLTAGE : 220-240V    -     50/60Hz

MONOPOLY OPERATION:

CUT 1 (Pure)                      Þ 80W    250Ω       0,92 MHz

CUT 2 (Blend)                    Þ 70W    250Ω       0,92 MHz

CONTACT COAGULATION    Þ 70W    200Ω       1,23 MHz

SPRAY COAGULATION         Þ 60W    400Ω       0,46 MHz

BIPOLAR OPERATION:

BIPOLAR COAGULATION     Þ 70W    50Ω         0,46 MHz

DIMENSIONS:                          295x136x280mm W x H x D

BAΡΟΣ:                                  5,2Κg περίπου

ΒΑΘΜΟΣ PROTECTION:        1

STANDARD:                           IEC 601-1,IEC601-2-2

MDD CLASSIFICATION:        CLASS IIB