{"id":7340,"date":"2019-08-01T20:48:54","date_gmt":"2019-08-01T17:48:54","guid":{"rendered":"https:\/\/getremed.gr\/newsite\/?post_type=product&#038;p=7340"},"modified":"2026-04-01T13:24:46","modified_gmt":"2026-04-01T10:24:46","slug":"r36m-%ce%ba%ce%bb%ce%b9%ce%bd%ce%b9%ce%ba%cf%8c%cf%82-%cf%84%cf%85%ce%bc%cf%80%ce%b1%ce%bd%ce%bf%ce%b3%cf%81%ce%ac%cf%86%ce%bf%cf%82-resonance-%ce%b9%cf%84%ce%b1%ce%bb%ce%af%ce%b1-%ce%b1%ce%bd%cf%84-2","status":"publish","type":"product","link":"https:\/\/getremed.gr\/eng\/product\/r36m-%ce%ba%ce%bb%ce%b9%ce%bd%ce%b9%ce%ba%cf%8c%cf%82-%cf%84%cf%85%ce%bc%cf%80%ce%b1%ce%bd%ce%bf%ce%b3%cf%81%ce%ac%cf%86%ce%bf%cf%82-resonance-%ce%b9%cf%84%ce%b1%ce%bb%ce%af%ce%b1-%ce%b1%ce%bd%cf%84-2\/","title":{"rendered":"R36m clinical tympanograph RESONANCE Italy"},"content":{"rendered":"<p>The clinical tympanograph performs: Tympanometry, Acoustic Reflex, Reflex Decay, Quick test: check, screening and Decay, Acoustic Reflex Latency test (ARLT), Multi-frequency Tympanometry, ETF (Intact perforated and patulous), Special tests (Growth-DLI and Non-acoustic).<\/p>\n<p><strong>Recordings<\/strong><\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 It has a built-in thermal printer<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 A pdf report is created directly from the device and saved to USB, with the ability to add patient details and comments via a wireless keyboard (optional)<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 It has pediatric audiometry<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Power supply 110-240 V AC 50\/60 Hz 40VA<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 It has dimensions of 370x290x180mm and weighs 3.5 kg.<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 ISO 13485, ISO 9001, MDD 93\/42\/EEC, Class IIa, IEC 60601-1, IEC 60601-1-2, IEC 60645-5\/ ANSI S.3.39 with CE and FDA approval.<\/p>\n<p><strong>Tympanometry features<\/strong><\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Intensity: 226Hz: 85dB SPL +-2dB 678, 800 and 1000Hz: 75dB SPL +-2dB Frequency accuracy +-0.5%<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Range at 226Hz: 0.05 to 7ml<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Sensitivity scale: Automatically adjusts to the appropriate range, available scales at 226Hz: 1.5, 2, 5, 7 ml<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Range at 678, 800, 1000Hz: 0 to +25mmho<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 HF sensitivity scale: Automatically adjusts to the appropriate range, available scales at 678, 800 and 1000Hz: 5,10, 15, 20, 25 mmho<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Pressure adjustment automatically and manually<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Range from +400 to -600daPa and from +200 to -400daPa, both adjustable in steps of 50daPa<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Pressure accuracy +-10daPa or +-10%<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u03a1\u03c5\u03b8\u03bc\u03cc\u03c2 \u03c3\u03ac\u03c1\u03c9\u03c3\u03b7\u03c2: 50,100,200, 300daPa\/sec \u03ba\u03b1\u03b9 \u03b1\u03c5\u03c4\u03cc\u03bc\u03b1\u03c4\u03b1<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Indicator: The measured value is displayed<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Protection limits: -800 to +600daPa<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Eustachian tube control function<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 ETF test for intact and perforated eardrums<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Also available is a test for a pulsatile tympanic membrane<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Reflex testing methods: Threshold, automatic and manual<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Stimulus duration: 0.5, 1, 2 seconds<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Ability to select protocols for all examination methods<\/p>\n<p>\u00b7 Ipsilateral and contralateral stimuli for all reflex tests<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Automatic peak search functions for all examination methods<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Manual Reflex: Manual control of all stimuli<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Reflex Decay: \u039c\u03b5\u00a0 \u03ba\u03b1\u03c4\u03ce\u03c6\u03bb\u03b9, \u03b1\u03c5\u03c4\u03cc\u03bc\u03b1\u03c4\u03b1 \u03ba\u03b1\u03b9 \u03c7\u03b5\u03b9\u03c1\u03bf\u03ba\u03af\u03bd\u03b7\u03c4\u03b1<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Stimulus duration 10 or 20 seconds<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 ARLT with threshold, automatic and manual<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Stimulus duration: 1 second<\/p>\n<p><strong>Ipsilateral reflexes<\/strong><\/p>\n<ul>\n<li>Tone level range (dB HL) from 50 to 110<\/li>\n<li>Noise level range (dB SPL) from 50 to 100<\/li>\n<li>Frequency: 500, 1000, 2000, 3000, 4000 Hz<\/li>\n<li>Noise: BBN, HP, LP<\/li>\n<li>Frequency accuracy: +-1%<\/li>\n<li>Harmonic distortion (THD): less than 3%<\/li>\n<\/ul>\n<p><strong>Unilateral reflexes<\/strong><\/p>\n<ul>\n<li>Tone level range (dB HL) from 50 to 120<\/li>\n<li>Noise level range (dB SPL) from 50 to 115<\/li>\n<li>Frequency: 250, 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz<\/li>\n<li>Noise: BBN, HP, LP<\/li>\n<li>Frequency accuracy: +-1%<\/li>\n<li>Calibration accuracy: +-3 dB<\/li>\n<li>Steps: 1,2,5,10 dB<\/li>\n<li>On\/off ratio 70dB minimum<\/li>\n<\/ul>\n<p>Includes:<\/p>\n<ul>\n<li>226Hz or HF nozzle<\/li>\n<li>Headband<\/li>\n<li>Nozzle handle<\/li>\n<li>Nozzle cleaning kit<\/li>\n<li>DD45 for Unilateral examination<\/li>\n<li>Entrance for contralateral<\/li>\n<li>Kit with nipples of various sizes from 6 mm to 15 mm.<\/li>\n<li>Calibration well with swab holder<\/li>\n<li>\u00a0Built-in thermal printer<\/li>\n<li>1 roll of paper with a width of 112 mm.<\/li>\n<li>Power cord (110-220 V)<\/li>\n<li>Protective cover<\/li>\n<li>User Manual<\/li>\n<li>Resonance MDS software including NoAH (demo version)<\/li>\n<li>1 extra fuse<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>The clinical tympanograph performs: Tympanometry, Acoustic Reflex, Reflex Decay, Quick test: check, screening and Decay, Acoustic Reflex Latency test (ARLT), Multi-frequency Tympanometry, ETF (Intact perforated and patulous), Special tests (Growth-DLI and Non-acoustic).<\/p>","protected":false},"featured_media":7070,"template":"","meta":[],"product_brand":[614],"product_cat":[486],"product_tag":[],"class_list":["post-7340","product","type-product","status-publish","has-post-thumbnail","product_brand-resonance","product_cat-akoologika","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product\/7340","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/media\/7070"}],"wp:attachment":[{"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/media?parent=7340"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product_brand?post=7340"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product_cat?post=7340"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product_tag?post=7340"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}