{"id":3516,"date":"2019-08-01T20:46:08","date_gmt":"2019-08-01T17:46:08","guid":{"rendered":"https:\/\/getremed.gr\/newsite\/?post_type=product&#038;p=3516"},"modified":"2026-04-01T13:24:56","modified_gmt":"2026-04-01T10:24:56","slug":"%cf%8137a-%ce%ba%ce%bb%ce%b9%ce%bd%ce%b9%ce%ba%cf%8c%cf%82-%ce%b1%ce%ba%ce%bf%ce%bf%ce%b3%cf%81%ce%ac%cf%86%ce%bf%cf%82-resonance-%ce%b9%cf%84%ce%b1%ce%bb%ce%af%ce%b1","status":"publish","type":"product","link":"https:\/\/getremed.gr\/eng\/product\/%cf%8137a-%ce%ba%ce%bb%ce%b9%ce%bd%ce%b9%ce%ba%cf%8c%cf%82-%ce%b1%ce%ba%ce%bf%ce%bf%ce%b3%cf%81%ce%ac%cf%86%ce%bf%cf%82-resonance-%ce%b9%cf%84%ce%b1%ce%bb%ce%af%ce%b1\/","title":{"rendered":"R37a clinical audiograph RESONANCE Italy"},"content":{"rendered":"<p>The clinical audiologist performs: Pure tone test, Autothreshold, ABLB, Speech, Stenger, DLI,SISI, Bekesy, Tone Decay, MLB, Multifrequency, GAP, DLF, high frequency at 20 KHz<\/p>\n<p>&nbsp;<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 It has a built-in thermal printer<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 A pdf report is created directly from the device and saved to USB, with the ability to add patient details and comments via a wireless keyboard (optional)<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Connection Ports Nr. 1 USB host type A. Nr.1 \u200b\u200bUSB slave type B<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Windows compatible software Resonance MDS Management Data Suite<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Power supply 110-240 V AC 50\/60 Hz 40VA<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Dimensions 370x290x180mm and weight: 3.5 kg.<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 ISO 13485, ISO 9001, MDD 93\/42\/EEC, Class IIa, IEC 60601-1, EMC: IEC 60601-1-2,<\/p>\n<p>&nbsp;<\/p>\n<p>Audiometry features<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Frequency range:<\/p>\n<p>125-8000Hz (\u03bc\u03b5 DD45)<\/p>\n<p>125-12500Hz (\u03bc\u03b5 HDA280)<\/p>\n<p>8000-20000Hz (\u03bc\u03b5 HDA300)<\/p>\n<p>250-8000Hz (\u03bc\u03b5 B71W)<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Range from -10 to 120dB HL<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Frequency Accuracy &lt;0.5%<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Distortion Accuracy &lt;1%<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Linear attenuation with 1dB step for every 5dB with a maximum of 3dB for the entire range<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u0391\u03ba\u03bf\u03bf\u03bc\u03b5\u03c4\u03c1\u03af\u03b1 \u039a\u03b1\u03b8\u03b1\u03c1\u03bf\u03cd \u03c4\u03cc\u03bd\u03bf\u03c5: \u03b7\u03bc\u03b9\u03c4\u03bf\u03bd\u03b9\u03ba\u03cc \u03c3\u03ae\u03bc\u03b1 \u03b1\u03c0\u03cc 125 \u03b5\u03ce\u03c2 8KHz (\u03c9\u03c2 20KHz \u03b3\u03b9\u03b1 HDA300)<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Audiometry with frequency modulation: +- 5% of the frequency of the modulated signal, 5 Hz signal modulation<\/p>\n<p>Narrowband noise: 24dB\/ filtered noise<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Speech noise: 1 KHz 12dB\/filtered noise<\/p>\n<p>&nbsp;<\/p>\n<p>Outputs<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 ACR,ACL: 10\u03a9 DD45 headphones, alternatively HDA280 Sennheiser. IP30 headphones<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 ACR,ACL up to 20KHz: HDA300 Sennheir<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 BC: B71W Radioear, B81<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 600\u03a9 free field output<\/p>\n<p>&nbsp;<\/p>\n<p>Viewing and shaping stimuli<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Display: Normal, inverted, extended (sounds are presented for 1 second from 20 dB below maximum)<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Modulation: Continuous or pulsed signal (0.5, 1, 2 Hz) DLI levels<\/p>\n<p>0.1 in steps from 20dB to 1.0 dB, 1.5, 2,3,4,5 dB<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 DLI increment levels: 0.5, 1, 2 Hz<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 SISI gain levels: 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5 dB<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Bekesy: Continuous, pulsed \u00a0Examination duration 30 and 60 seconds<\/p>\n<p>&nbsp;<\/p>\n<p>Basic accessories<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 DD45, ADC or HDA280 headphones and audiometry test<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 HDA300 headphones for high frequency testing<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 B71W bone conductor<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Converter<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Operator headset with microphone<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Patient microphone for response<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Internal speaker for monitoring<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Patient response button<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Built-in thermal printer<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1 roll of paper with a width of 112 mm.<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Power cable (110-220 V)<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Protective cover<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 User Manual<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 SD card with speech material in multiple languages<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Resonance MDS software including NoAH (demo version)<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1 extra fuse<\/p>","protected":false},"excerpt":{"rendered":"<p>The clinical audiologist performs: Pure tone test, Autothreshold, ABLB, Speech, Stenger, DLI,SISI, Bekesy, Tone Decay, MLB, Multifrequency, GAP, DLF, high frequency at 20 KHz<\/p>","protected":false},"featured_media":7068,"template":"","meta":[],"product_brand":[614],"product_cat":[486],"product_tag":[],"class_list":["post-3516","product","type-product","status-publish","has-post-thumbnail","product_brand-resonance","product_cat-akoologika","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product\/3516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/media\/7068"}],"wp:attachment":[{"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/media?parent=3516"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product_brand?post=3516"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product_cat?post=3516"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/getremed.gr\/eng\/wp-json\/wp\/v2\/product_tag?post=3516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}